OK, if you get a 'nothing to print' message for your posting journal, but Year End says that there is, then your data is out of synch. The internal posting sequence range doesn't match the data file GLPJRPYR.dat.
When you select the prior year, do you see a sequence range or is in 'blank to blank'? This is important as it will determine the required steps.
If 'blank to blank', then the above data file has a size greater than zero bytes. Something prevented the data file from being cleared when the report was printed and purged. The solution is to rename this file.
If a sequence shows, then the program is expecting information in the above data file that isn't there. The cause is usually that the data file was manually removed rather than printing/purging the report. The usual solution is to post something (to prior year) to generate a new sequence for the journal report, and print and purge all sequences. This likely won't be available to you, as Post to Prior Year will be disabled. Data would need to be repaired.
The first (easier) scenario is likely the problem, as Year End looks at the posting journal data files, not the internal sequence not yet purged.
_________________________
Regards,
Softrak Tech Support