Hi Brian,

Scan Data from other Systems (OE and Invoices) has always been for the same data location and extension, and has never allowed browsing to a different company. Same thing for Retrieve data - always just for the same company with no browsing elsewhere.

If you want to copy the retrieval file from OE 9.2A, that file is OESSISY.dat.

Please make sure that you have the SalesAnalysis 9.2A (2016.06.08) service pack installed if you choose to copy that file from one place to another, in the case where the live OE data is at one location, but the intention is to send the created OESSISY data file to a different place. The reason is that when creating the 'dummy' SalesAnalysis data at the OE site, the version of SA you quoted had a problem during the data creation process - and thus caused problems in OE and the invoice audit list area.

If you have already created the dummy SR data for the satellite OE locations, there may be a missing line in the SRWININI.dat data file, that you could use a text editor to manually put in to solve a potential problem (which really is to indicate to SalesAnalysis to look for a 'new style' file):

[ConversionOE81D]
Done=1

Hope this helps.


Edited by Softrak Support (07/21/16 04:44 PM)
Edit Reason: more information