Joined: Feb 2002
Posts: 301
Adagio Specialist
|
|
Adagio Specialist
Joined: Feb 2002
Posts: 301 |
A client has installed the recent SalesCQ upgrade and get the message “unable to find data dictionary ar customer extention @R80BCSE, 1212” when opening Quotes. Would this be a result of not installing Receivables 9.0A? They are reluctant to upgrade receivables at the moment until they find out if their custom mod to OE impacts the Receivables upgrade.
|
|
|
|
|
Joined: Mar 2002
Posts: 10
Adagio Pro
|
|
Adagio Pro
Joined: Mar 2002
Posts: 10 |
Compatibility chart says it is compatible. Maybe needs a service pack?
Kate Spontak Stief Group New Jersey, the Garden State
|
|
|
|
|
Joined: Mar 1999
Posts: 11,746
Adagio Action Team
|
|
Adagio Action Team
Joined: Mar 1999
Posts: 11,746 |
Hi Lars,
The dictionary quoted in the '1212' error is @R80BCSE, and the version number 80B is contained within. So the problem is not that Receivables 90A is missing and required, otherwise the dictinary error would have quoted a dictionary table with 90A somewhere within.
What are the file dates of the @R80B?.SSI dictionaries in the \softrak\dict directory? The likely problem is that they have the wrong or missing AR80B dictionary. I believe that the correct dates should both be March 3, 2010.
Regards, Softrak Tech Support
|
|
|
|
|
Joined: Feb 2002
Posts: 301
Adagio Specialist
|
|
Adagio Specialist
Joined: Feb 2002
Posts: 301 |
Both files are dated March 4, 2010.
|
|
|
|
|
Joined: Mar 1999
Posts: 11,746
Adagio Action Team
|
|
Adagio Action Team
Joined: Mar 1999
Posts: 11,746 |
Hi, Lars,
Sounds like another install was done on March 4th and changed the date of some of the dictionaries to the date of the install rather than maintaining their own file dates. This is known to happen with Microsoft when an install is done while logged onto the server console.
Rename the files and install the CQ upgrade again so that the files will update. Hopefully, those were the only dictionary file dates that were changed by the prior install.
Regards, Softrak Tech Support
|
|
|
|
|
Joined: Mar 1999
Posts: 10,504
Adagio Master
|
|
Adagio Master
Joined: Mar 1999
Posts: 10,504 |
I'd be surprised if SalesCQ installs the Receivables 8.0 dictionary. That's pretty old.
Andrew Bates
|
|
|
|
|
Joined: Mar 1999
Posts: 11,746
Adagio Action Team
|
|
Adagio Action Team
Joined: Mar 1999
Posts: 11,746 |
Both SalesCQ and Receivables install these dictionaries. This is the same dictionary used for Receivables 8.1A, the version immediately prior to 9.0A.
Regards, Softrak Tech Support
|
|
|
|
|
Joined: Feb 2002
Posts: 301
Adagio Specialist
|
|
Adagio Specialist
Joined: Feb 2002
Posts: 301 |
Client renamed @R80B?.SSI files and reinstalled SlesCQ. Everything now works.
Thanks for all your help!
|
|
|
|
0 members (),
77
guests, and
3
robots. |
|
Key:
Admin,
Global Mod,
Mod
|
|
|
Forums5
Topics14,679
Posts71,625
Members1,874
| |
Most Online1,408 Dec 9th, 2025
|
|
|
S |
M |
T |
W |
T |
F |
S |
|
1
|
2
|
3
|
4
|
5
|
6
|
7
|
|
8
|
9
|
10
|
11
|
12
|
13
|
14
|
|
15
|
16
|
17
|
18
|
19
|
20
|
21
|
|
22
|
23
|
24
|
25
|
26
|
27
|
28
|
|
29
|
30
|
|
|
|
|
|
|
|
|
|
|